Product Specifications:
Input voltage : AC: 9V~ 24V (AC Frequence: 50HZ/60HZ): DC: 9V~30V
Working current : ≤80mA@12V (Imax =150mA),
Power consumption:≤0.96W
Sensing distance : 0.3m~ 8m@reflectivity (10%-90%)
Reaction time : ≥ 100mS
Ambient light resistance : Max.70Klux
Signal reception angle : 2° Product output interface : GND/AC、VCC/AC、NO/NC、COM
Product output type : Relay dry contact output (NO/NC is selected by product jumper)
LED light indication:Green LED light: 1) It is mainly used to indicate the power-on status of the product; 2) It is used to indicate the distance setting mode and working mode switching;
Yellow LED light: working status signal indication (On/Off: light off when there is an obstacle / light on when thereis no obstacle.)
Product Size(L*W*H) :100 * 40 * 35mm
Product standard :One photocell sensor, one manual, one hood (optional)
Productinstallation:
When debugging and installing,make sure that there are no obstacles within the set sensing distance;
When installing the product,try to avoid direct sunlight;
The minimum height for product installation is 1 meter,and it is recommended to be greater than 1 meter;When setting the sensing distance of the product,it must be more than 0.3 meters;
Do not power up the sensor until all electrica lwiring to the sensor has been completed;