YET845A Motor Controller RF version-V5.0

November 22, 2022
YET845A Motor Controller RF version-V5.0

It aslo supports WiFi internal or external network connection:can be control as a single product or network [Multi-product].

At the same time it supports Smart Link network access technology:simple and convenient network access.

Product specificsation:

§ Input voltage:100V AC-220V AC

§ Relay contact current 10A@250VAC / 10A@277VAC / 12A@120VAC

§ Control output 0.5A-5A(Adjust by adjustable resistor)

§ Standby power consumption <2.2W (stand-by current:≤10mA@220VAC)

§ Running time Max: 4 minutes Min: 5 seconds Wireless standard IEEE802.11b/g/n

§ Working frequency 2.4G ~2.5G(2400M ~2483.5M)Hz 433MHZ/315MHZ(Customizable)

§ Encryption type WEP/TKIP/AES

§ Security mechanism WPA/WPA2

§ Storage Environment temperature: -30℃ ~ +80℃ humidity: 20% ~ 93%

§ Receiver sensitivity :802.11 b: -91 dbm (11 Mbps)

                                    802.11 g: -75 dbm (54 Mbps)

§ Size 122*77*40mm

§ Remote control capacity:400pcs buttons(equivalent to 100 pcs 4- buttons remotes)

Production function description:

§ Controller system mode setting(Dip switch setting) : Swithch the direction of opening and closing doors,Single button cycle/Four buttons independeent,Auto delay closing door function activated,Indicator light mode/Flash light mode

§ Controller decoding mode seeting (Dip switch setting ):learning code (1527 code),rolling code (301 code ),open code (fixed code /learning code/rolling code ) 

§ Automatic door closing with delay:Max :4 minutes Min :5 seconds

§ 4 key independent mode/ 1 key mode for your choice

§ Lighting function of the controller 

§ Rebound function in case of resistance

§ 

Ø Note:

1) When the electric door is closing (down), if the user switches to open (up) or stop, the

maximum running time will be reset; if the electric door encounters an obstacle, the system

will delay 0.5S before starting control The electric door opens (upward) action. 3) When using the AC auto-delayed door closing function, the system starts timing and automatically closes the door; if the user presses the "C (stop/unlock)" button on the remote control during timing, the system timer will be cleared and restarted. 4) Status indicator description:

The controller power-on default status indicator flashes at a frequency of 1S, and flashes

quickly at a frequency of 250MS during the shutdown process, and restores to the default

state after the shutdown is completed; flashes at a frequency of 600MS during the startup

process, and restores the default state after the shutdown is completed (When the FLASH

flashing light is turned on, it is synchronized with the status indication). 5) When learning the remote control, the motor must be stopped; the effective time interval of continuously pressing the learning button is 1 second, and the controller will execute the corresponding function if the time interval is exceeded.


Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --
Chat with Us

Send your inquiry

Choose a different language
English
Xhosa
Tiếng Việt
Türkçe
ภาษาไทย
Polski
Bahasa Melayu
latviešu valoda‎
lietuvių
Latin
bahasa Indonesia
فارسی
Ελληνικά
български
русский
Português
italiano
français
Español
Deutsch
العربية
Slovenščina
Српски
Українська
Română
čeština
Current language:English