Compatible Door Types:
Electric Sliding Doors (Courtyard Retractable Gates, Industrial Sliding Gates): Most commonly used. Connected to the door motor controller. When the beam is blocked during closing, the motor stops/reverses to prevent pinching. It can also function as an intrusion alarm.
Electric Roller Shutters, High-Speed Stacking Doors, Industrial Lifting Doors: Installed on pillars on both sides of the doorway for intrusion prevention at entrances and exits. It can also serve as a signal input to the door motor control box for obstruction detection during closing.
Hinged Doors (Electric Hinged Gates): Installed on both sides of the wall to protect the doorway passageway and linked to the door motor.
Ordinary Metal Doors, Iron Doors, Warehouse Entrance Doors: Indoor and outdoor entrance security alarm. An alarm signal is output when someone passes through the doorway and blocks the beam.
Motor Compatibility Requirements:
The motor must have a control box (controller). The control board must have infrared beam signal input terminals (passive switch contacts). The detector outputs a dry contact signal to the control box. The detector must not be directly connected in series with the motor's main circuit power supply.
The motor controller supports the following logic: Upon receiving an infrared disconnect signal, it executes stop closing and reverse opening; it automatically resets after an obstacle is removed.
Both DC and AC door motors are acceptable; the key is the control board signal interface, not the motor voltage.
II. Requirements for the Active Infrared Intrusion Detector Product Itself
1. Electrical and Output
Output: Passive relay dry contacts (normally open NO / normally closed NC switchable), contact capacity meets the door motor control board requirements, generally DC30V, 1-2A; it cannot be a dedicated alarm bus signal with open collector, otherwise it cannot connect to the door motor.
Response Time: Beam obstruction alarm time (40±10) ms; brief interference obstruction (≤20ms) does not trigger false alarms, suitable for rapid door motor operation scenarios.
Power Supply: Commonly DC12-24V, compatible with door motor control power supply;
2. Environmental Protection
Outdoor use: Protection level ≥ IP55, waterproof and dustproof; Indoor use ≥ IP41. Operating temperature: -25℃ to +55℃, adaptable to day and night temperature differences at outdoor doors; select the version with heater for low-temperature and frigid environments.
Light interference resistance: Resistant to direct sunlight, vehicle headlights, and fluorescent lights hitting the receiver, preventing false triggering.
For outdoor use, dual-beam/quad-beam is preferred, requiring simultaneous blocking of multiple beams to output a signal, avoiding false triggering due to single-beam obstruction by birds or fallen leaves; single-beam is only suitable for small indoor doorways.
Actual operating warning distance ≤ 2/3 of the product's nominal maximum distance, leaving a margin to ensure reliable operation in rainy or foggy weather.
III. Door and Motor Control System Requirements: The detector should be installed on fixed walls/posts on both sides of the doorway, not on the movable door leaf; the detector and cables should not be bumped or pulled during door operation.
Cables should be properly protected to avoid electromagnetic interference from the motor; signal lines and high-power motor wiring should be run separately.
The motor controller requires logic settings: distinguishing between "alarm mode" and "anti-pinch mode"; intrusion alarm is a continuous alarm; anti-pinch mode stops closing and reverses upon receiving a signal, automatically resuming operation when the obstacle disappears.